Basic Info.

Discharge Rate
Low Discharge Rate
Shape
Square Battery
Electrolyte
Acid
Installation
Packaged
Rechargeable
Chargeable
Weight
57.9kg ; 62.4kg
Certificate
CE; ISO; CNAS; MSDS
Sealed Type
Sealed
Terminal
F8
Maintenance Type
Free
Max. Discharge Current
3000A (5 Sec)
Transport Package
Carton and Wooden Box by Sea
Specification
522mm*240mm*219/223mm
Trademark
Sunpal
Origin
China
HS Code
8507200000
Production Capacity
1000PCS/Per Day

Product Description

Product Description
Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery SystemReplacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery System
Battery Configuration

Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery SystemBattery Terminal Options
Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery System

Product Parameters
Model
6-GFM(G)-100Ah
6-GFM(G)-150Ah
6-GFM(G)-200Ah
6-GFM(G)-250Ah
Cells Per Unit
6
Voltage Per Unit
12V
Capacity
100Ah@10hr-rate to 1.80V per cell @25°C
150Ah@10hr-rate to 1.80V per cell @25°C
200Ah@10hr-rate to 1.80V per cell @25°C
250Ah@10hr-rate to 1.80V per cell @25°C
Weight
29kg
42kg
58.5kg
67kg
Internal Resistance
Approx. 6mΩ
Approx. 4mΩ
Approx. 3.5mΩ
Approx. 2.5mΩ
Terminal
F1/F2
Max. Discharge Current
1500A(5s)
2250A(5s)
3000A(5s)
3750A(5s)
Design Life
10~15 years
Maximum Charging Current
25A
37.5A
50A
62.5A
Float Charging Voltage
13.6 V~13.8 V @ 25°C
Temperature Compensation: -20mV/°C/Cell
Cycle Use Voltage
14.4 V~14.9 V @ 25°C
Cycle Use Voltage
Temperature Compensation: -30mV/°C/Cell
Operating Temperature Range
Discharge: -20°C~60°C
Charge: 0°C~50°C
Storage: -20°C~60°C
Container Material
A.B.S. UL94-HB, UL94-V0 Optional.

 Advantages:
1. High purity lead-tin alloy, reduce battery self discharge rate and increase battery service life.
2. ABS battery case made by LG raw material to increase battery service life.
3. Heat sealing technique instead of glue sealing to increase the tightness and stability of battery.
4. TTP technique not only reduce internal resistance and material cost but also increase battery life.
5. Conduct four large current discharge texting before package to insure battery quality.
6. Full charge before delivery. Buy and use it directly.

Characteristics Data
Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery System

Detailed Photos

Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery System

Packaging & Shipping

Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery SystemReplacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery System

Our Factory

 

Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery SystemReplacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery System
FAQ
1.How long can a battery last?
The service design life of a battery varies considerably with how it is used, how it is maintained and charged, temperature, among other factors.
 
2.Do I need to add water to my battery?
No. Sealed lead acid batteries do not require the use of water.
 
3.What determines the life of a VRLA battery?
Sealed lead acid battery life is determined by many factors. These include temperature, depth and rate of discharge, and the number of charges and discharges (called cycles).
 
4.What is the difference between float and cycle applications?
A float application requires the battery to be on constant charge with an occasional discharge. Cycle applications charge and discharge the battery on a regular basis.
 
5.What is the definition of "cycle use" and "standby use"?
"Cycle Use" - direct power source: Cycle Use - IT can provide the power supply to power tools, and portable electronic products.It can also be used for cycling charging and discharging usage such as electronics motorbike or vacuum cleaner.
"Standby Use" - back up power: Standby Use is mainly used for emergency power to avoid future damage that may be caused by a sudden power outage.
 
6.When should a deep-cycle battery be used?
Deep-cycle batteries are used when 50% or more of the capacity is used per cycle. The most common use of deep-cycle batteries is in applications that require deep, repetitive drain, like powerful car audio systems, trolling motors, golf carts, electric wheelchairs, or RV house power sources. Public safety and high performance vehicles are other applications that call for the special characteristics of deep-cycle batteries.
 
7.How are batteries rated?
Lead acid batteries are rated based on a capacity given in a defined time. There is not a set industry standard for how to rate a battery.
 
Request Complete System

Replacement High Quality Lead Acid Battery Separaters Recycle Plant for Solar Panel Battery System

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours